1 | | Flange with gasket | | |
3 | | Gasket | | |
4 | | Ti electrode with connecting cable | | |
5 | | Temperature sensor | | |
9 | | Angled panel | | |
10 | | R.h. side panel | | |
11 | | L.h. side panel | | |
12 | | Front panel, bottom | | |
13 | | Front panel, top | | |
15 | | Lower thermal insulation | | |
16 | | Container hose | | |
17 | | Drip container | | |
18 | | Safety valve | | |
19 | | Circulation pump motor UPS 60 | | |
20 | | 3/2-way valve with stepper motor | | |
22 | | Pressure gauge | | |
23 | | Retainer, plug-in connector | | |
24 | | Drain valve R 1/2" | | |
25 | | Shut-off valve DN 20 | | |
28 | | Gasket set | | |
29 | | Sealing washer Ø21.0 x 30.0 x 2.0 | | |
30 | | Fixing elements | | |
31 | | Circulation pump motor VIZ 25/5-3 | | |
32 | | Plate-type heat exchanger | | |
33 | | Diaphragm safety valve 3 bar | | |
34 | | Three-way ball valve G 1" | | |
35 | | Fill valve DN 20 | | |
36 | | Quick acting air vent valve G 3/8" | | |
37 | | Connecting pipe HV | | |
38 | | Thermocouple | | |
39 | | Temperature sensor | | |
40 | | Grommets (set) | | |
41 | | Profiled gasket | | |
42 | | Safety spring | | |
43 | | Heat exchangers | | |
44 | | Siphon connection | | |
46 | | O-ring Ø28 x 2.5 | | |
47 | | Boiler flue connection plug | | |
48 | | Pressure gauge and fem. Connection | | |
49 | | Boiler flue connection Ø60/100 | | |
50 | | Burner door | | |
51 | | Ignition unit | | |
53 | | Insulation ring | | |
54 | | Burner gauze assembly | | |
55 | | Burner gauze assembly gasket | | |
58 | | Fan outlet gasket | | |
59 | | Radial fan | | |
60 | | Mixer | | |
61 | | Gas train | | |
62 | | Plug-in connector retainers (set) | | |
64 | | Hook-in lock (set) | | |
65 | | Cap panel with gaskets | | |
66 | | Gas supply pipe | | |
67 | | Connection pipe HR | | |
68 | | Ventilation air gasket Ø100 | | |
69 | | Lip seal Ø60 | | |
70 | | Diaphragm expansion vessel 10 l | | |
71 | | Connection line; diaphragm expansion vessel | | |
72 | | Back panel lid | | |
73 | | Clip nut | | |
74 | | Plug-in connector gasket set | | |
80 | | Vitodens control unit | | |
81 | | Back cover | | |
82 | | Support | | |
83 | | Flap | | |
84 | | Pressure gauge retainer | | |
85 | | Clip (10 pce.) | | |
86 | | Hinge (10 pce.) | | |
87 | | Internal extension H1 | | |
88 | | LON module | | |
89 | | Adaptor PCB | | |
90 | | Boiler coding card | | |
91 | | Fuse 6.3 A slow (10 pce.) | | |
92 | | Programming unit | | |
95 | | Locking clips (10 pcs.) | | |
110 | | Outside temperature sensor | | |
112 | | Flue gas temperature sensor | | |
120 | | Locking handle | | |
121 | | Cylinder temperature sensor | | |
122 | | Hinge pins (10 pce.) | | |
127 | | Impressed current anode PCB | | |
129 | | Vitosolic 100 | | |
130 | | Overflow valve | | |
131 | | Pivoting arm l.h./r.h. | | |
144 | | Connection adaptor PCB | | |
150 | | T&P valve | | |
52 | | Burner gasket | | |
56 | | Ignition electrode | | |
57 | | Ionisation electrode | | |
45 | | Special grease | | |
62 | | Burner maintenance set | | |
63 | | Set of small burner parts | | |
93 | | Cable harness X8/X9 | | |
94 | | Cable harness 100/35/34 (auxiliary earth) | | |
96 | | Cable harness X3 | | |
97 | | Cable 96/40/X7 | | |
98 | | Cable X2/Vitosolic | | |
99 | | Power cable, stepper motor | | |
100 | | Ionisation cable | | |
101 | | Internal ionisation cable | | |
102 | | Connection cable, impressed current anode | | |
103 | | Connecting cable X7/Vitosolic | | |
104 | | Adaptor, ionisation current test cable | | |
105 | | Cable X6/LED impressed current anode | | |
140 | | Touch-up paint stick, Vitowhite | | |
141 | | Spray paint, Vitowhite | | |
142 | | Installation and service instructions | | |
143 | | Operating instructions | | |